01How much heat the house loses
The single biggest driver. A room-by-room heat loss calculation sets the size of the heat pump or the number of heaters. A draughty stone cottage needs more output than a well-insulated bungalow of the same floor area, and more output costs more.
02Radiators and pipework
Heat pumps run at lower water temperatures than a boiler, so some radiators may need to be larger. Narrow microbore pipework sometimes needs replacing. Your survey says room by room which radiators stay and which change.
03Hot water cylinder
Most heat pump installations need a hot water cylinder. If you have a combi boiler today, there is no cylinder, and space has to be found for one — often in an airing cupboard, loft conversion or utility room.
04Where the outdoor unit goes
A short, simple run from the outdoor unit to the cylinder costs less than a long run across a garden or through a thick stone wall. Flats and tenements may need permission from neighbours or the factor before anything is fixed to a shared wall.
05Electrical supply
Older homes sometimes need a consumer unit upgrade, and some properties need the network operator to check the incoming supply. This is confirmed on the survey rather than guessed at.
06Fabric work first
Loft insulation, draught-proofing or cavity wall insulation may be needed before any low-carbon system makes sense. That work is costed separately, and it often lowers the size, and therefore the price, of the heating system itself.